Angelbiss Oxygen Supply System
Angelbiss Care engineering
> Can support customised production
> Can support overseas installation
> Can support long termed after sales technical service
Technical Index
Compressed Air Pressure |
0.7-1.3MPa(7Bar-13Bar) |
Oxygen Capacity |
3 - 200Nm3/h |
Oxygen Purity |
93%+-2% |
Outlet Pressure |
0.30MPa(Oxygen Generator)/15MPa(Filling Manifold) |
Dew Point |
≤-40ºC |
Electrical Power |
~380V/3P/50Hz or Customized |
PSA Oxygen Generator Specification
Model |
Capacity (Nm3/hr) |
Air consumption (Nm3/min) |
Inlet (mm) |
Outlet (mm) |
Air pretreatment |
SZC- 6 |
6 |
1.9 |
25 |
15 |
SZ-2 |
SZC- 10 |
10 |
2.8 |
32 |
15 |
SZ-3 |
SZC- 20 |
20 |
5.6 |
40 |
20 |
SZ-6 |
SZC- 30 |
30 |
8.4 |
50 |
20 |
SZ-10 |
SZC- 50 |
50 |
14 |
65 |
25 |
SZ-15 |
SZC- 80 |
80 |
22 |
65 |
32 |
SZ-25 |
SZC- 100 |
100 |
28 |
80 |
32 |
SZ-30 |
SZC- 150 |
150 |
42 |
100 |
40 |
SZ-50 |
SZC- 200 |
200 |
56 |
125 |
40 |
SZ-60 |
Product features
1. Full Automation
All systems are designed for un-attended operation and automatic Oxygen demand adjustment.
2. Lower Space Requirement
The design and Instrumentation makes the plant size very compact, assembly on skids, prefabricated and supplied from factory.
3. Fast Start-up
Start-up time is about 30 minutes to get desired Oxygen purity. So these units can be switched ON & OFF as per Oxygen demand changes.
4. High Reliability
It's very reliable for continuous and steady operation with constant Oxygen purity. Plant availability time is better than 93% always.
5. Zeolite Molecular Sieves Life
Expected Zeolite Molecular Sieves life is more than 10-years i. e. Whole life time of Oxygen plant. So no replacement costs.
6. Low investment and energy consumption
7. Simple operation and maintenance
After sales service
1- If the oxygen concentrator fails to be repaired, please contact our service center.
2- Maintenance service work can only be performed by technical engineers authorized by our company.
3- In order to ensure the long-term use of this oxygen concentrator, users are requested to strictly follow the guidelines for safety, cleaning and maintenance of the oxygen concentrator, and to use and maintain the operation methods that are beneficial to the normal operation of the oxygen concentrator
Before servicing, disconnect the power.
1. Do not open the oxygen concentrator shell. There are no user-maintainable parts inside
the oxygen concentrator.
2. The internal repair and maintenance of the oxygen concentrator can only be performed
by an agency authorized by AngelBiss. Do not attempt to repair the oxygen concentrator yourself.
Disposal
Except for specially designated oxygen concentrator parts and packaging boxes, please dispose of them or return them to our company for disposal in accordance with relevant national laws and regulations.
Choose AngelBiss, Now level up faithfullness of our health